Note: a) Of the 18 reagents used in the chemical resistance
             test, only sulfuric acid concentrate caused a deterioration of


             the decking   system.
             b)  Wearing  surface  revealed  no  cracking,  crazing,

            delamination, or any other deleterious effects.

             c) The test specimens which were coded “No. 2 or 3” could

             not be restored to their original surface condition by normal

             cleaning methods.


             11. Low  Temperature  Flexibility:  AC  39  Sec.  K.  5°F.  No
            cracking     or  crazing  upon  visual  examination  under  5x

             magnification in the bent condition.

             12.Fire  Resistance  Test  Series  Class  “A”:  U.B.C.  Standard



             32-7,  ASTM  E-108,  U.L.790,  N.F.P.A.  No.  256,  Spread  of
             Flame Test (2 decks) on concrete surfaces.      B)

            Spread of Flame Test (2 decks):

                                    Base (in.)    Length (in.)
             Deck 1                    15            18
             Deck 2                    15            27

             Max. Flame Spread Allowed   40          72
            Poly-I-Gard  246 SF vehicular deck system will satisfactorily
                    ®
            withstand the Flame Spread portion of the test for Class A
             Rating in UBC STD #32-7, ASTM E108, UL 790 and NFPA
             No. 256, when constructed, installed and tested as described
             herein.


































           ______________________________________________________________________________________________________________________________________
           Limited Warranty:
           Please read all information in the general guidelines, product data sheets, guide specifications and material safety data sheets (MSDS) before applying material. Published technical data and instructions are subject to
           change without notice. Contact your local Polycoat Products representative or visit our website for current technical data and instructions.

           Polycoat Products warrants its products to be free of manufacturing defects and that they will meet Polycoat Products current published physical properties. Polycoat Products warrants that its products, when properly installed by a state
           licensed  waterproofing  contractor  according  to  Polycoat  Products  guide  specifications  and  product  data  sheets  over  a  sound,  properly  prepared  substrate,  will  not  allow  water  migration  for  a  period  of  one  (1)  year.  Seller’s  and
           manufacturer’s sole responsibility shall be to replace that portion of the product of this manufacturer which proves to be defective. There are no other warranties by Polycoat Products of any nature whatsoever expressed or implied,
           including any warranty of merchantability or fitness for a particular purpose in connection with this product. Polycoat Products shall not be liable for damages of any sort, including remote or consequential damages resulting from any
           claimed breach of any warranty whether expressed or implied. Polycoat Products shall not be responsible for use of this product in a manner to infringe on any patent held by others. In addition, no warranty or guarantee is being issued
           with respect to appearance, color, fading, chalking, staining, shrinkage, peeling, normal wear and tear or improper application by the applicator. Damage caused by abuse, neglect and lack of proper maintenance, acts of nature and/or
           physical movement of the substrate or structural defects are also excluded from the limited warranty. Polycoat Products reserves the right to conduct performance tests on any material claimed to be defective prior to any repairs by owner,
           general contractor, or applicator.

           Disclaimer:
           All guidelines, recommendations, statements, and technical data contained herein are based on information and tests we believe to be reliable and correct, but accuracy and completeness of said tests are not guaranteed and are not to be
           construed as a warranty, either expressed or implied. It is the users responsibility to satisfy himself, by his own information and test, to determine suitability of the product for his own intended use, application and job situation and user
           assumes all risk and liability resulting from his use of the product. We do not suggest or guarantee that any hazard listed herein are the only ones which may exist. Neither seller nor manufacturer shall be liable to the buyer or any third
           person for any injury, loss or damage directly or indirectly resulting from use of, or inability to use, the product. Recommendations or statements, whether in writing or oral, other than those contained herein shall not be binding upon the
           manufacturer, unless in writing and signed by a corporate officer of the manufacturer. Technical and application information is provided for the purpose of establishing a general profile of the material and proper application procedures.
           Test performance results were obtained in a controlled environment and Polycoat Products makes no claim that these tests or any other tests, accurately represent all environments.

                                                                      ®
                                                                Testing & Approvals  -  Poly-I-Gard   246SF                                               Page 2 of 2

                    14722 Spring Ave  Santa Fe Springs, CA 90670-5108 USA  Tel: 562-802-8834  Fax: 562-921-7363  www.polycoatusa.com  Copyright ® November  2012 Polycoat Products