Page 21 - tmp
P. 21

TECHNICAL DATA SHEET
                                                                                        THEMECOAT  751-FR
                                                                                                         ®
                                                                     Fire Retardant Two Component Aromatic Hybrid
                                                                                     Polyurethane Protective Coating



            PRODUCT DESCRIPTION
            Themecoat  751-FR is a Class 1 fire-rated, fast set, rapid curing,   TECHNICAL DATA (Based on Draw Down Films)
                     ®
            aromatic, two component hybrid polyurea/polyurethane   Mix Ratio                                 1A : 1B
            spray designed to be applied over EPS, wood, and many
            other surfaces. Its excellent balance of stiffness and impact   Pot Life                     4-6 seconds
            resistance provides excellent plastic “shell-like”  protection
            for delicate foams and EPS. Themecoat  751-FR’s chemical   Tack Free Time                  30-60 seconds
                                              ®
            design allows fast “user-friendly” application with excellent   Recoat Time                   0-12 hours
            flow and appearance.
                                                                  Viscosity at 150-160ºF (66.6-71ºC),
            FEATURES                                              Brookfield:
              •  1:1 Mix Ration By Volume                         Side-A                                 100 ± 50 cps
                                                                  Side-B
                                                                                                         150 ± 50 cps
              •  100% Solids
                                                                                                         10.27 lbs/gal
              •  Excellent Chemical Protection                    Density (Side A & B Combined)        (1230  kgs/m )
                                                                                                                  3
              •  Excellent Cold Temperature Impact Resistance
                                                                                                              >200ºF
              •  Excellent Thermal Stability                      Flash Point                               (>93.3ºC)
              •  Fast Cure
              •  High Productivity                                Hardness, ASTM D-2240*                     75 ± 5%
              •  Low Shrinkage                                    Tensile, ASTM 412-C*                  3200 ± 300 ps
              •  Meets ASTM E-84 Class 1 Fire Test Criteria                                            (21 MPa ± 2.1)
              •  Plastic “Shell-Like” Protection                  Elongation, ASTM 412-C*                 15% ± 10%
              •  Zero VOC
                                                                  Tear, ASTM 624-C*                       400 ± 50 pli
            TYPICAL USES                                                                                   (70 kN/m)
              •  Architectural Shapes                             Service Temperature                   -20ºF to 300ºF
              •  Decorations / Props                                                                      (-29-149ºC)
              •  Dock Flotations
              •  Food Processing Plants                            (*These physical properties from sample  sprayed  with  Graco  Foam Cat
                                                                   200 @ 2000 psi (32 MPa) minimum, with Gusmer GX7-400 mechanical
              •  Speaker Boxes                                     purge gun @ 150-160°F (66-72ºC). Different machine and parameter will
              •  Steel Coating                                     change these properties. User should perform their own independent
              •  Wood Cabinets                                     testing as properties are approximate).
              •  Wood Pallets / Crates
            PACKAGING
            10-gallon kit: 5 gallon (18.9 liters) pail of Side-A and 5-gallon   of the substrate to which they are applied. All surfaces must
            (18.9 liters) pail of Side-B.                        be free of dust, dirt, oil, grease, rust, corrosion and other
                                                                 contaminants. When coating substrates previously used, it is
            100-gallon kit: 50 gallon (189 liters) drum of Side-A and   important to consider the possibility of substrate absorption,
            50-gallon (189 liters) drum of Side-B.               which may affect the adhesion of the coating system, regard-
                                                                 less of the surface preparation. Polycoat recognizes the
            COLORS                                               potential for unique substrates from one project to another.
            Clear/Neutral/Tan. Custom colors are available upon request.   The following information is for general reference, and for
            Color Packs, when used, must be added to Side-B.     project-specific questions, contact Polycoat
            Due to its aromatic composition, Themecoat  751-FR will tend   NEW AND OLD CONCRETE:
                                                ®
            to yellow or darken in color and will become flat after exposure   Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5. New
            to UV light. Themecoat  751-FR may be topcoated within   concrete must be cured for 28 days prior to product applica-
                                ®
            twelve hours of application with an aliphatic polyurethane/  tion. Surface must be clean, dry, sound and offer sufficient
            polyurea coating for a colorfast finish.             profile for product adhesion. Remove all dust, dirt, oil, form
            COVERAGE                                             release agents, curing compounds, salts, efflorescence,
            Themecoat  751-FR may be applied at any rate to achieve   laitance and other foreign matter by shotblasting and/or
                      ®
            desired thickness. Theoretical coverage for 1 mil thickness  is   suitable chemical means, in accordance with local chemical
            one gallon per 1600 sqft (7.78 liters per 149 sqm).  regulations. Rinse thoroughly, to achieve a pH between 8.0 and
                                                                 11.0. Allow to dry completely. If old concrete has a surface that
            SURFACE PREPARATION                                  has deteriorated to an unacceptably rough surface, Polycoat
            In general, coating performance and adhesion are directly   Products PC-260 or a mixture of Polyprime 21 and sand should
            proportional to surface preparation. Most failures in the perfor-   be used as a repair agent for cracks, spalls, bug holes and
            mance of surface coatings can be attributed to poor surface   voids. Upon full cure of the repair agent, prime the entire
            preparation. Polyurea coatings rely on the structural strength   surface intended for coating.



        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363
        info@polycoatusa.com  |  www.polycoatusa.com
   16   17   18   19   20   21   22   23   24   25   26