Application                                          Limitations
         Apply Polyglaze® 100/100C/100SC evenly over the entire deck.   The following conditions must not be coated with Polycoat
         For best results, airless sprayer or phenolic resin core roller   deck coatings or systems: split slabs, buried membrane,
         may be used but extra care should be taken not to cause air   sandwich slabs with insulation, slabs over unvented metal
         bubbles.                                             pan, magnesite, and non-structural lightweight concrete. On
                                                              grade slabs may receive Polycoat system coatings provided
         Polyglaze® 100/100C/100SC may require more than one coat   a moisture-vapor transmission test is first performed. Please
         depending on the job specifications and requirements. When   contact Polycoat’s technical department with the results.
         estimating material requirements, coverage rates tend to
         increase for subsequent coats of material. To achieve proper   With regard to coating asphalt surfaces, please contact
         adhesion between coats it is imperative that recoating be   Polycoat’s technical department.
         done within 48 hours.
                                                              Surfaces must be dry, clean and free of foreign matter.
         When Polyglaze® 100/100C/100SC Clear is used as a seal coat   Clear coating may turn opaque and cloudy due to moisture
         only, the surface must be clean, dry and primed with Polyprime    penetration, especially in exterior applications. Surface may
                                                           ®
         U to achieve proper adhesion to the surface. Polyprime  may   be slippery when wet. Containers that have been opened
                                                       ®
         discolor when used under Polyglaze® 100/100C/100SC Clear   must be used as soon as possible. Do not dilute under any
         as a seal coat.                                      circumstance.
         Requires a continuous coating application to minimize lines   Warning
         and/or streaking.                                    This product contains Isocyanates and Solvent.
         Curing                                               Polyglaze® 100/100C/100SC Clear is considered Dangerous Goods. DOT
         At 75°F (24°C) and 50% relative humidity, allow each coat   regulations classify it as: UN 1263, PAINT, Class 3, PG III, Flammable
         to cure 16 hours between each coat.  Cure time will vary   Liquid.
         depending on temperature and humidity.
         Allow 24 hours before permitting light pedestrian traffic and
         at least 72 hours before permitting heavy pedestrian or auto
         traffic on to the finished surface. If more than 48 hours passes
         between coats, re-prime the surface with Polyprime  U before
                                                    ®
         proceeding.
         If accelerated curing is required, add one quart (0.95 liter) of
         Polyglaze® Hardener in a 5 gallon pail (18.9 liters) of Polyglaze®
         100/100C/100SC and mix thoroughly. This accelerated
         Polyglaze®100/100C/100SC will cure in 6-8 hours at 75°F (24°C)
         and 50% relative humidity. The re-coat time with accelerator
         is reduced to 24 hours. If the re-coat window has passed,
         then solvent wipe the surface with VOC compliant solvent
         and re-prime surface with Polyprime  U before proceeding
                                         ®
         to the next coat.
         Cleanup
         Equipment should be cleaned with an environmentally safe
         solvent, as permitted under local regulations, immediately
         after use.
         Storage
         Polyglaze® 100 has a shelf life of 1 year from date of manufacture
         in original, factory-sealed containers when stored indoors at
         a temperature between 60-95°F (15-35°C).





        Limited Warranty: Please read all information in the General Guidelines, Technical Data Sheets, Guide Specifications and Safety Data Sheets (SDS) before applying material. These
        products are for professional use only and preferably applied by professionals who have prior experience with the Polycoat Products materials or have undergone training in application
        of Polycoat Products materials. Published technical data and instructions are subject to change without notice. Contact your local Polycoat Products representative or visit our website for
        current technical data, instructions, and project specific recommendations.
        Polycoat Products warrants its products to be free of manufacturing defects and that they will meet Polycoat Products’ current published physical properties. Seller’s and manufacturer’s
        sole responsibility shall be to replace that portion of the product which proves to be defective. There are no other warranties by Polycoat Products of any nature whatsoever expressed or
        implied, including any warranty of merchantability or fitness for a particular purpose in connection with this product. Polycoat Products shall not be liable for damages of any sort, including
        remote or consequential damages resulting from any claimed breach of any warranty whether expressed or implied. Polycoat Products shall not be responsible for use of this product in a
        manner to infringe on any patent held by others. In addition, no warranty or guarantee is being issued with respect to appearance, color, fading, chalking, staining, shrinkage, peeling, normal
        wear and tear or improper application by the applicator. Damage caused by abuse, neglect and lack of proper maintenance, acts of nature and/or physical movement of the substrate or
        structural defects are also excluded from the limited warranty. Polycoat Products reserves the right to conduct performance tests on any material claimed to be defective prior to any repairs
        by owner, general contractor, or applicator.
        Disclaimer: All guidelines, recommendations, statements, and technical data contained herein are based on information and tests we believe to be reliable and correct, but accuracy and
        completeness of said tests are not guaranteed and are not to be construed as a warranty, either expressed or implied. It is the user’s responsibility to satisfy himself, by his own information and
        test, to determine suitability of the product for his own intended use, application and job situation and user assumes all risk and liability resulting from his use of the product. We do not suggest
        or guarantee that any hazard listed herein are the only ones which may exist. Neither seller nor manufacturer shall be liable to the buyer or any third person for any injury, loss or damage directly
        or indirectly resulting from use of, or inability to use, the product. Recommendations or statements, whether in writing or oral, other than those contained herein shall not be binding upon the
        manufacturer, unless in writing and signed by a corporate officer of the manufacturer. Technical and application information is provided for the purpose of establishing a general profile of the
        material and proper application procedures. Test performance results were obtained in a controlled environment and Polycoat Products makes no claim that these tests or any other tests
        accurately represent all environments. Polycoat Products is not responsible for typographical errors. © 2020 Polycoat Products. All rights reserved. Revision 20200917.DM

        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363                                           Section 7.1
        wpsales@polycoatusa.com  |  www.polycoatusa.com
   132   133   134   135   136   137   138   139   140   141   142