Page 19 - Polycoat 10.2 Technical Data Sheet Polycaulk 82
P. 19

Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5.  New   hour prior to application using heavy duty drum agitator.
        concrete must be cured for 28 days prior to product applica-  Both Side-A and Side-B lines must have filters removed. Use
        tion. Surface must be clean, dry, sound and offer sufficient   a round pattern disc for spraying. Orifice diameter must be
        profile for product adhesion. Remove all dust, dirt, oil, form   0.042” or greater.
        release agents, curing compounds, salts, efflorescence,
        laitance and other foreign matter by shotblasting and/or   Recommended surface temperature must be at least 5°F (3°F)
        suitable chemical means, in accordance with local chemical   above the dew point.
        regulations. Rinse thoroughly, to achieve a pH between 8.0 and   Polyeuro  MPL 11 FR should be applied using a plural
                                                                      ®
        11.0. Allow to dry completely. If old concrete has a surface that   component, heated, high pressure 1:1 spray mixing equip-
        has deteriorated to an unacceptably rough surface, Polycoat   ment like Graco’s Reactor, Glass Craft or other equivalent
        Products PC-260 or a mixture of Polyprime 21 and sand should   machine may be used.
        be used as a repair agent for cracks, spalls, bug holes and
        voids.  Upon full cure of the repair agent, prime the entire   Both Side-A and Side-B materials should be sprayed at a
        surface intended for coating.                         minimum of 2000 psi and at temperatures above 150°F (66°C).
                                                              Adequate pressure and temperature should be maintained
        CONCRETE SURFACE PREPARATION REFERENCE                at all times.
        ASTM D4258 - Standard practice for cleaning concrete ASTM    ®
        D4259 - Standard practice for abrading concrete ASTM D4260 -   Polyeuro  MPL 11 FR should be sprayed in smooth, multi-
        Standard practice for etching concrete ASTM F1869 - Standard   directional passes to improve uniform thickness and ap-
        test method for measuring moisture vapor emission rate of   pearance.
        concrete                                              Storage
                                                                     ®
        ICRI 03732 - Concrete surface preparation             Polyeuro  MPL 11 FR has a shelf life of twelve (12) months
                                                              from date of manufacture, in factory-sealed containers.  at a
        WOOD                                                  temperature between 60-95°F (15-35°C).
        All wood should be clean, dry and free of any knots, splinters,
        oil, grease or other contaminants.  Splintered or rough areas   Side-A and Side-B drums are recommended to be stored
        should be sanded.  Knots should be repaired using Polycoat   above 60°F (15°C). Avoid freezing temperatures.
        Products PC-260 with sand.  Upon full cure of the repair agent,   Store drums on wooden pallets to avoid direct contact with
        prime the entire surface intended for coating.        the ground. If stored for a long period of time, rotate Side-A
                                                              and Side-B drums regularly.
        STEEL (ATMOSPHERIC AND IMMERSION EXPOSURE)
        Remove all oil, grease, weld spatters and round off any sharp  Limitations
        edges from surface. Minimum surface preparation is Near   Do not open until ready to use.
        White Metal Blast Cleaning per SSPC-SP10/NACE 2. Opti-mum   Both Side-A and Side-B containers must be fitted with a
        surface profile is 2-3 mils. Prime with recommended primer   desiccant device during use.
        and spray Polyeuro  MPL-11FR on to any bare metal the same
                        ®
        day as it is cleaned to minimize any potential flash rusting.  Warning
        GALVANIZED SURFACES                                   This product contains Isocyanates and Curative Material.
        Clean and degrease any contaminated surfaces before
        priming.  Do not blast galvanized surfaces with an abrasive
        grit. An adhesion test is recommended prior to starting the
        project. Primer may be needed, consult Polycoat.
        FIBERGLASS REINFORCED PLASTIC
        The gel coat should be lightly blasted or sanded with 80 grit
        sandpaper and cleaned.

        TEXTILES, CANVAS, FABRICS
        Adhesion to most fabrics, geothermal membranes and tex-
        tiles does not require a primer.
        NEW AND OLD CAST IRON:
        Blast with a steel grit and degrease before priming. Old cast
        iron is difficult to prepare for a satisfactory bond.  It can
        absorb oil and water soluble contaminants that will keep
        returning to the surface after the coating system has been
        applied and affect the coating system adhesion. An adhesion
        test is recommended prior to starting the project.
        MIXING
        Polyeuro  MPL 11 FR may not be diluted under any circum-
                ®
        stances. Thoroughly mix Polyeuro  MPL 11 Side-A and Side-B
                                    ®
        with air driven power equipment until a homogeneous mix-
        ture and color is obtained.
        Application
        Both Side-A and Side-B materials should be preconditioned
        to 90-100°F (32-42°F) before application.
        Both Side-A and Side-B materials should be continuously
        agitated before and during application. Agitate at least one


        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363
        wpsales@polycoatusa.com  |  www.polycoatusa.com