Page 13 - Polycoat 10.2 Technical Data Sheet Polycaulk 82
P. 13

TECHNICAL DATA SHEET
                                                                                                        ®
                                                                                          POLYEURO  LP-1188
                                                               Two Component Modified Polyurea Protective Coating





            Product Description
            Polyeuro  LP-1188 is a two component, 1:1.88, 100% solids,   Technical Data (Based on Draw Down Film)
                   ®
            fast set, liquid applied, modified polyurea liner system for   Mix Ratio by Volume              1A : 1.88B
            metal, concrete, fiberglass, and wood surfaces.
                                                                  Pot Life @ 80ºF (26ºC)                 12-16-Seconds
             Features                                             Tack Free Time (150 mils thickness)    40-60 Seconds
              •  Abrasion and Impact Resistant                    Recoat Time                              6 - 12 hours
              •  Chemical Resistance                              Viscosity at 80°F (26°C), Brookfield
              •  High Build                                       Side-A                                   700-900 cps
                                                                  Side-B
                                                                                                           700-900 cps
              •  Low Pressure Application
              •  Low Temperature Flexibility                      Density (Side-A & Side-B Combined)        9.2 lbs/gal
              •  Quick Drying                                     Flash Point                           > 200°F (93.3°C)
              •  Seamless                                         Hardness, ASTM D2240                   91-93 Shore A
              •  Tough and Elastomeric                            Tensile Strength, ASTM D412*           1300 ± 200 psi
                                                                                                        8.96 ± 1.38 MPa
             Typical Uses
                                                                  Elongation, ASTM D412*                  250% ± 50%
               •  Boat Linings                                    Tear Resistance, ASTM D412*              175 ± 25 pli
               •  Cargo Holds                                                                           30.6 ± 4.37 kNm
               •  Cargo Liners                                    Service Temperature Dry                -20ºF to 200ºF
               •  Encapsulation of Fiberglass Bodies                                                       30ºC - 93ºC
               •  Horse Trailers                                  NOTE: Above physicals are from lab drawn films. Actual spray physicals may vary.
               •  Mold Castings
               •  Truck Bed Surfaces                             and other contaminants. When coating substrates previously
               •  Utility Vehicles                               used, it is important to consider the possibility of substrate
               •  Walkways                                       absorption, which may affect the adhesion of the coating
               •  Waterproof Decking                             system, regardless of the surface preparation. Polycoat
                                                                 recognizes the potential for unique substrates from one project
             Packaging                                           to another. The following information is for general reference,
                                                                 and for project-specific questions, contact Polycoat.
              One 55 gallon drum net content 500 lbs (227 kgs) of Side-A   NEW AND OLD CONCRETE
              and two 55 gallon drum net content 450 lbs (204 kgs) each   Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5.  New
              drum of Side-B                                     concrete must be cured for 28 days prior to product applica-
                                                                 tion. Surface must be clean, dry, sound and offer sufficient
            Colors                                               profile for product adhesion. Remove all dust, dirt, oil, form
            Clear/Neutral or Black. Custom colors are available upon   release agents, curing compounds, salts, efflorescence,
                                                                 laitance and other foreign matter by shotblasting and/or
            request. Color packs, when used, must be added to Part-B.
                                                                 suitable chemical means, in accordance with local chemical
            Due to its aromatic composition, Polyeuro  LP-1188 will tend to   regulations. Rinse thoroughly, to achieve a pH between 8.0 and
                                              ®
            yellow or darken in color after exposure to UV light. Polyeuro    11.0. Allow to dry completely. If old concrete has a surface that
                                                              ®
            LP-1188 may be topcoated within twelve hours of application   has deteriorated to an unacceptably rough surface, Polycoat
            with an aliphatic polyurethane/polyurea coat-ing for a colorfast   Products PC-260 or a mixture of Polyprime 21 and sand should
            finish.                                              be used as a repair agent for cracks, spalls, bug holes and
            Coverage                                             voids.  Upon full cure of the repair agent, prime the entire
                                                                 surface intended for coating.
            Polyeuro  LP-1188 may be applied at any rate to achieve desired
                   ®
            thickness. Theoretical coverage for 1 mil (0.254 microns)   CONCRETE SURFACE PREPARATION REFERENCE
            thickness is one gallon per 1600 sqft (3.78 liters per 149 sqm).  ASTM D4258 - Standard practice for cleaning concrete
            Estimating Formula: (1600 sqft per gal /Dry Mil Thickness) x   ASTM D4259 - Standard practice for abrading concrete
            Solids Content = Application Rate per gallon.        ASTM D4260 - Standard practice for etching concrete
                                                                 ASTM F1869 - Standard test method for measuring moisture
            Surface Preparation                                                   vapor emission rate of concrete
            In general, coating performance and adhesion are directly   ICRI 03732 - Concrete surface preparation
            proportional to surface preparation. Most failures in the
            performance of surface coatings can be attributed to poor   WOOD
            surface preparation. Polyurea coatings rely on the structural   All wood should be clean, dry and free of any knots, splinters,
            strength of the substrate to which they are applied. All sur-  oil, grease or other contaminants.  Splintered or rough areas
            faces must be free of dust, dirt, oil, grease, rust, corrosion   should be sanded.  Knots should be repaired using Polycoat



        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363
        wpsales@polycoatusa.com  |  www.polycoatusa.com
   8   9   10   11   12   13   14   15   16   17   18