Page 9 - Polycoat 10.2 Technical Data Sheet Polycaulk 82
P. 9

TECHNICAL DATA SHEET
                                                                                                           ®
                                                                                             POLYEURO  LP-11
                                                               Two Component Modified Polyurea Protective Coating





            Product Description
            Polyeuro  LP-11 is a two component, 1:1, 100% solids, fast   Technical Data (Based on Draw Down Film)
                   ®
            set, liquid applied, modified polyurea liner system for metal,   Mix Ratio by Volume              1A : 1B
            concrete, fiberglass and wood surfaces.               Pot Life @ 80ºF (26ºC)                 12-16-Seconds
             Features                                             Tack Free Time (150 mils thickness)    40-60 Seconds
                                                                  Recoat Time                              6 - 12 hours
              •  Abrasion and Impact Resistant
              •  Chemical Resistance                              Viscosity at 80°F (26°C), Brookfield    400-500 cps
                                                                  Side-A
              •  High Build                                       Side-B                                  700-900 cps
              •  Low Pressure Application                         Density (Side-A & Side-B Combined)       9.22 lbs/gal
              •  Low Temperature Flexibility
              •  Quick Drying                                     Flash Point                           > 200°F (93.3°C)
              •  Seamless                                         Hardness, ASTM D2240                   91-93 Shore A
              •  Tough and Elastomeric                            Tensile Strength, ASTM D412*           2000 ± 300 psi
                                                                                                       13.78 ± 2.07 MPa
             Typical Uses                                         Elongation, ASTM D412*                  250% ± 50%
               •  Boat Linings                                    Tear Resistance, ASTM D412*              175 ± 25 pli
               •  Cargo Holds                                                                           30.6 ± 4.37 kNm
               •  Cargo Liners                                    Service Temperature Dry                -20ºF to 200ºF
               •  Encapsulation of Fiberglass Bodies                                                       -30ºC - 93ºC
               •  Horse Trailers                                  NOTE: Above physicals are from lab drawn films. Actual spray physicals may vary.
               •  Mold Castings
               •  Truck-Bed Surfaces                             strength of the substrate to which they are applied. All sur-
               •  Utility Vehicles                               faces must be free of dust, dirt, oil, grease, rust, corrosion
               •  Walkways                                       and other contaminants. When coating substrates previously
               •  Waterproof Decking                             used, it is important to consider the possibility of substrate
                                                                 absorption, which may affect the adhesion of the coating
             Packaging                                           system, regardless of the surface preparation. Polycoat
                                                                 recognizes the potential for unique substrates from one project
              10-gallon kit   5 gallons (18.9 liters) Side-A and 5   to another. The following information is for general reference,
                              gallons (18.9 liters) Side-B       and for project-specific questions, contact Polycoat.
                                                                 NEW AND OLD CONCRETE
              100-gallon kit  50 gallons (189 liters) Side-A and 50   Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5.  New
                              gallons (189 liters) Side-B        concrete must be cured for 28 days prior to product applica-
                                                                 tion. Surface must be clean, dry, sound and offer sufficient
                                                                 profile for product adhesion. Remove all dust, dirt, oil, form
            Colors                                               release agents, curing compounds, salts, efflorescence,
            Clear/Neutral or Black. Custom colors are available upon   laitance and other foreign matter by shotblasting and/or
            request. Color packs, when used, must be added to Side-B.  suitable chemical means, in accordance with local chemical
            Due to its aromatic composition, Polyeuro  LP-11 will tend to   regulations. Rinse thoroughly, to achieve a pH between 8.0
                                               ®
            yellow or darken in color after exposure to UV light. Polyeuro    and 11.0. Allow to dry completely. If old concrete has a surface
                                                              ®
            LP-11 may be topcoated within twelve hours of application   that has deteriorated to an unacceptably rough surface,
            with an aliphatic polyurethane/polyurea coating for a colorfast   Polycoat Products PC-260 or a mixture of Polyprime 21 and
            finish.                                              sand should be used as a repair agent for cracks, spalls, bug
                                                                 holes and voids.  Upon full cure of the repair agent, prime
            Coverage                                             the entire surface intended for coating.
            Polyeuro  LP-11 may be applied at any rate to achieve desired   CONCRETE SURFACE PREPARATION REFERENCE
                   ®
            thickness. Theoretical coverage for 1 mil (0.254 microns)   ASTM D4258 - Standard practice for cleaning concrete
            thickness is one gallon per 1600 sqft (3.78 liters per 149 sqm).  ASTM D4259 - Standard practice for abrading concrete
            Estimating Formula: (1600 sqft per gal /Dry Mil Thickness) x   ASTM D4260 - Standard practice for etching concrete
            Solids Content = Application Rate per gallon.        ASTM F1869 - Standard test method for measuring moisture
                                                                                   vapor emission rate of concrete
            Surface Preparation                                  ICRI 03732 - Concrete surface preparation
            In general, coating performance and adhesion are directly
            proportional to surface preparation. Most failures in the   WOOD
            performance of surface coatings can be attributed to poor   All wood should be clean, dry and free of any knots, splinters,
            surface preparation. Polyurea coatings rely on the structural


        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363
        wpsales@polycoatusa.com  |  www.polycoatusa.com
   4   5   6   7   8   9   10   11   12   13   14