Note:  a)  Of  the  18  reagents  used  in  the  chemical   STM C-957-93 (Ramtech Report #10988-97)
              resistance  test,  only  sulfuric  acid  concentrate  caused  a   1. Dry Film Thickness: 4 coats,  47 ± 2 mils (0.12 ± 0.005 cm)


              deterioration of the decking system.
             b)  Wearing  surface  revealed  no  cracking,  crazing,   2. Weight Loss: ASTM 957-93, C-836 (max. 40%): 13.8%

             delamination, or any other deleterious effects.

             c)  The  test  specimens  which  were  coded  “No.  3  -   3. Low Temperature Flexibility and Crack Bridging: 10 cycles,

              Considerably  Affected”  could  not  be  restored  to  their   d" movement, @ -15°F: Passed

              original surface condition by normal cleaning methods.

                                                                 4.  Adhesion  in  Peel:  after  water  immersion  (7  days,  min.  5
             11.  Low  Temperature  Flexibility:  AC  39  Sec.  K.  5°F.  No   lbs/in.), ASTM 957-93, C-794: 14 lbs/in
             cracking    or  crazing  upon  visual  examination  under  5x

             magnification in the bent condition.                5.  Chemical  Resistance:  ASTM  C-957,  D-471:  Meets
                                                                 minimum requirements
              12. Fire    Resistance Test Series Class “B”: AC 39 Section
                                                                                             Actual   Minimum C-957

              IV  C.  U.B.C.  Standard  15-2,  ASTM  E-108,  U.L.790,          Tensile, psi   % of Control  Requirements
             N.F.P.A. No. 256, on b" (1.6 cm) plywood.           Control         1102         N/A           --

             A) Intermittent Flame Exposure Test (2 decks): Both of the   Water   1046         95          70

              decks met the requirements for Class B Intermittent Flame   Ethylene Glycol   934   85       70

              Exposure  Test.  There  was  no  evidence  of  displacement,   Mineral Spirits   854   78    45

              sliding, spalling, or flames underneath these decks during
             or after the test.                                  6. Weather Resistance and Recovery from Elongation: ASTM
             B) Spread of Flame Test (2 decks): Base (in.)  Length (in.)   C-957-93, D-412: Meets minimum requirements.
             Deck 1                         21         54                      Elongation    Tensile
              Deck 2                        18         43                     Recovery (%)  Strength (psi)  Elongation (%)
              Max. Flame Spread Allowed     40         72        Control      91.2 (2 hrs.)   1069         97.2

              C) Burning Brand Test (4 decks): Both decks passed. No          98.4 (24 hrs.)
             flaming  or damage occurred underneath decks.  The  heat            84.3
             areas  were  confined  to  the  immediate  area  of  brand   Weathered   90.3 (2 hrs.)   1164   90
             placement.  There  was  no  displacement  of  the  Polydeck      96.9 (24 hrs.)
              355 System observed during or after the test.                      81.4
              Polydeck 355 Decking System will satisfactorily withstand   % of Control   99 (2 hrs.)   108.8%   92.6%

              the three methods of tests for a Class B Rating on concrete      98.5 (24 hrs.)
             substrates and Class B rating on b" plywood in UBC STD              96.5%
             #32-7,  ASTM  E108,  UL  790  and  NFPA  No.  256,  when
              constructed, installed and tested as described herein.   7. Abrasion Test: ASTM C-957-93, C-501, weight loss
                                                                 (Maximum allowed:  0.050 grams): 0.045 grams

              13.  One-Hour  Fire-Resistive  Construction:  Based  on  the
             performance  of  the  test  assembly,  Polydeck 355 Walking
             Deck  System  installed  on  b"  thick  C-D  plywood  as  a
              substitute  for  the  double  wood  floor  described  in
              Construction  No.  13,  Item  13-1.1,  Table  No.  7-C  of  the

              1994 U.B.C. Standard No. 7-1. The assembly was tested
             with 2 X 10 floor joists spaced at 16 inches on center.
             The average room temperature rise on the unexposed face
             was 260°F and the maximum single thermometer reading
              was 310°F after 65 minutes. The acceptance limit is 250°F
              average temperature rise with no single reading over 350°F
              above ambient after 60 minutes. The area under the  test

             time  vs.  temperature  curve  equals  the  standard  time-
             temperature E-119 curve at 60.56 minutes.





           ______________________________________________________________________________________________________________________________________
           Limited Warranty:
           Please read all information in the general guidelines, product data sheets, guide specifications and material safety data sheets (MSDS) before applying material. Published technical data and instructions are subject to
           change without notice. Contact your local Polycoat Products representative or visit our website for current technical data and instructions.

           Polycoat Products warrants its products to be free of manufacturing defects and that they will meet Polycoat Products current published physical properties. Polycoat Products warrants that its products, when properly installed by a state
           licensed  waterproofing  contractor  according  to  Polycoat  Products  guide  specifications  and  product  data  sheets  over  a  sound,  properly  prepared  substrate,  will  not  allow  water  migration  for  a  period  of  one  (1)  year.  Seller’s  and
           manufacturer’s sole responsibility shall be to replace that portion of the product of this manufacturer which proves to be defective. There are no other warranties by Polycoat Products of any nature whatsoever expressed or implied,
           including any warranty of merchantability or fitness for a particular purpose in connection with this product. Polycoat Products shall not be liable for damages of any sort, including remote or consequential damages resulting from any
           claimed breach of any warranty whether expressed or implied. Polycoat Products shall not be responsible for use of this product in a manner to infringe on any patent held by others. In addition, no warranty or guarantee is being issued
           with respect to appearance, color, fading, chalking, staining, shrinkage, peeling, normal wear and tear or improper application by the applicator. Damage caused by abuse, neglect and lack of proper maintenance, acts of nature and/or
           physical movement of the substrate or structural defects are also excluded from the limited warranty. Polycoat Products reserves the right to conduct performance tests on any material claimed to be defective prior to any repairs by owner,
           general contractor, or applicator.

           Disclaimer:
           All guidelines, recommendations, statements, and technical data contained herein are based on information and tests we believe to be reliable and correct, but accuracy and completeness of said tests are not guaranteed and are not to be
           construed as a warranty, either expressed or implied. It is the users responsibility to satisfy himself, by his own information and test, to determine suitability of the product for his own intended use, application and job situation and user
           assumes all risk and liability resulting from his use of the product. We do not suggest or guarantee that any hazard listed herein are the only ones which may exist. Neither seller nor manufacturer shall be liable to the buyer or any third
           person for any injury, loss or damage directly or indirectly resulting from use of, or inability to use, the product. Recommendations or statements, whether in writing or oral, other than those contained herein shall not be binding upon the
           manufacturer, unless in writing and signed by a corporate officer of the manufacturer. Technical and application information is provided for the purpose of establishing a general profile of the material and proper application procedures.
           Test performance results were obtained in a controlled environment and Polycoat Products makes no claim that these tests or any other tests, accurately represent all environments.

                                                                    ®
                                                                Testing & Approvals  -  Polydeck  355                                               Page 2 of 2

                    14722 Spring Ave  Santa Fe Springs, CA 90670-5108 USA  Tel: 562-802-8834  Fax: 562-921-7363  www.polycoatusa.com  Copyright ® November 2012 Polycoat Products
   88   89   90   91   92   93   94   95   96   97   98