Page 57 - Polycoat 1.1 Table of Contents
P. 57
GUIDE SPECIFICATIONS | Section 2.11
POLYDECK MR
®
rates are calculated on theoretical coverage for a smooth
substrate and do not account for the actual texture or substrate
conditions in the field or at the time of application. Sample
mockups on the projects are recommended to determine the
exact coverage rates necessary to waterproof the deck to
acceptable standards.
Equipment should be cleaned with a urethane grade
environmentally safe solvent, as permitted under local
regulations, immediately after use. Uncured materials
are sensitive to heat and moisture. The substrate must be
structurally sound and sloped for proper drainage. Polycoat
Products assumes no liability for substrate defects. Field visits
by Polycoat Products personnel are for the purpose of making
technical recommendations only and are not to supervise or
provide quality control on the job site.
Warning
The products in this system contain Isocyanates, Solvents, Epoxy Resin,
and Curatives.
POLYCOAT PRODUCTS TEL 562.802.8834 | FAX 562.921.7363 Section 2.11
wpsales@polycoatusa.com | www.polycoatusa.com