Page 56 - tmp
P. 56

TECHNICAL DATA SHEET I SECTION  3.9
                                                                                                            ®
                                                                                             POLYEURO  5851
                                                                                          Two Component, Aromatic
                                                                                         Polyurea Protective Coating



            Product Description                                   Technical Data
            Polyeuro  5851 is a 100% solids, rapid curing, odorless,
                    ®
            flexible, two component, aromatic-spray polyurea developed   Mix Ratio by Volume                  1A : 1B
            for specialty application such as a geotextile lining membrane.   Pot Life @ 75ºF (24ºC), 50% R.H.  15-25 seconds
            It may also be applied to concrete and steel substrates.
            Polyeuro  5851 is volatile free, and mixed at a 1:1 ratio with   Tack Free Time (thickness & substrate   120-150 seconds
                   ®
            plural-component- spray equipment.                    temperature dependent)
                                                                  Recoat Time                              0 - 12 hours
             Features                                             Viscosity at 80°F (27ºC), Brookfield   1200 ± 150 cps
                                                                  Side-A
              •  100% Solids                                      Side-B                                 400 ± 100 cps
              •  ANSI/GRHC/SPRI VR-1 (2001) Compliant             Density (Side-A & Side-B Combined)    8.5 ± 0.5 lbs/gal
              •  Excellent Thermal Stability                      Flash Point                           > 200°F (93.3°C)
              •  Exposure Temperatures -40ºF to 350ºF  (-40ºC to 177ºC)  Hardness, ASTM D2240                85 ± 5 A
              •  FLL  Root Resistance
                                                                                                         3500 ± 200 psi
              •  Good Chemical Resistance                         Tensile Strength, ASTM D412          24.13 ± 1.37 MPa
              •  Immediate Return to Service
              •  Low-Curing Stress Shrinkage                      Elongation, ASTM D412                     250 ± 50%
                                                                                                           350 ± 50 pli
              •  Odorless                                         Tear Strength, ASTM D624               61.3 ± 8.8 kNm
              •  Seamless
              •  Zero VOC                                         Service Temperature                    -40°F to 300°F
                                                                                                         -40°C to 121°C
             Typical Uses                                         *These physical properties from sample sprayed with Graco EXP2 @ 2000 psi minimum, with
                                                                  Fusion Gun AP4242 @ 150-160°F (65°C to 71°C)  blistering. Color change, gloss reduction &
              •  Flexible Membranes                               chalking are noted. Different machine and parameter will change these properties.  User should
                                                                  perform their own independent testing as properties are approximate.
              •  Foam Coatings
              •  Geotextile Coatings                             Surface Preparation
              •  Industrial and Manufacturing Facilities         In general, coating performance and adhesion are directly
              •  Liners                                          proportional to surface preparation. Most failures in the
              •  Oil Production Water/Condensate Containments    performance of surface coatings can be attributed to poor
              •  Structural Steel                                surface preparation. Polyurea coatings rely on the structural
                                                                 strength of the substrate to which they are applied. All surfaces
              •  Typical Ambient Waste Water/Condensate          must be free of dust, dirt, oil, grease, rust, corrosion and other
               Containments                                      contaminants. When coating previously used substrates, it is
              •  Waterproofing Membranes                         important to consider the possibility of substrate absorption,
                                                                 which may affect the adhesion of the coating system,
                                                                 regardless of the surface preparation. Polycoat recognizes
              Packaging                                          the potential for unique substrates from one project to another.
                                                                 The following information is for general reference. For project-
              10-gallon kit   5 gallons (18.9 liters) and 5 gallons   specific questions, contact Polycoat.
                              (18.9 liters) Side-B               NEW AND OLD CONCRETE
                                                                 Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5.  New
              100-gallon kit  50 gallons (189 liters) Side-A and 50   concrete must be cured for 28 days prior to product application.
                              gallons (189 liters) Side-B        Surface must be clean, dry, sound and offer sufficient profile
                                                                 for product adhesion. Remove all dust, dirt, oil, form release
                                                                 agents, curing compounds, salts, efflorescence, laitance and
            Colors                                               other foreign matter by shotblasting and/or suitable chemical
            Petro Tan, Industrial  Tan, Carlsbad Canyon, and Covert Green.   means, in accordance with local chemical regulations. Rinse
            Custom colors are available upon request.            thoroughly to achieve a pH between 8.0 and 11.0. Allow to dry
                                                                 completely. If old concrete has a surface that has deteriorated
            Coverage                                             to an unacceptably rough surface, PC-260 or a mixture of
                                                                          ®
            Polyeuro  5851 may be applied at any rate to achieve desired   Polyprime  21 and sand should be used as a repair agent
                   ®
            thickness. Theoretical coverage for 1 mil (0.254 microns)   for cracks, spalls, bug holes and voids.  Upon full cure of the
            thickness is one gallon per 1600 sqft (3.78 liters per 149 sqm)   repair agent, prime the entire surface intended for coating.
            Estimating Formula: (1600 sqft per gal /Dry Mil Thickness) x   CONCRETE SURFACE PREPARATION REFERENCE
            Solids Content = Application Rate per gallon.        ASTM D4258 - Standard practice for cleaning concrete.
                                                                 ASTM D4259 - Standard practice for abrading concrete.



        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363                                        Section 3.9
        info@polycoatusa.com  |  www.polycoatusa.com