Page 22 - tmp
P. 22

TECHNICAL DATA SHEET I SECTION 2.5
                                                                                             POLYPRIME 3042
                                                                                                            ®
                                                                                                    Two Component,
                                                                                             Epoxy-Polyamide Primer



            Product Description
            Polyprime  3042 is a two component, NSF-61 approved liquid  Technical Data (Based on Draw Down Film)
                    ®
            applied epoxy primer.  This primer has been developed for
            use on carbon steel, non-ferrous metal, fiberglass, PVC pipe,   Coverage Rate              1 gal/300 sqft
            as well as concrete and masonry.                                                              0.14 l/sqm

             Features                                              Dry Film Thickness per                4.5 ± 1 mils
                                                                   Coat                             102 ± 25 microns
              •  Low Viscosity Epoxy Coating
              •  Provides Limited Chemical Resistance
              •  Surface Tolerant Primer/Sealer                    Mixing Ratio                              2A:1B
              •  Versatile Application: Spray, Roll or Brush
              •  UL-NSF-61 Approved For Potable/Drinking           Pot Life at 75ºF (24ºC),               20-30 min
                                                                   50% RH
             Typical Uses
               •  Chemical & Pharmaceuticals Industries            Specific Gravity,                       1.12 ± 0.1
               •  Concrete Floors and Decks                        Side-A                                 1.06 ± 0.1
                                                                   Side-B
               •  Food Processing Facilities
               •  Industrial Flooring
               •  Mining and Milling Industry                      Total Solids by Weight,                  91 ± 2%
                                                                   ASTM D2369
               •  Petrochemical Plants
               •  Power Generating Plants                          Total Solids by Volume,                  90 ± 2%
               •  Pulp and Paper Industry                          ASTM D2697
               •  Steel Structures and Bridges
               •  Water & Wastewater Treatment Plants
                                                                   Viscosity at 75°F (24°C)           1200 ± 200 cps
             Packaging
                                                                   Volatile Organic
                                                                   Compounds,                             0.75 lb/gal
              3-Gallon Kit            One 3.5 gallon pail, net fill 2                                   90 gm/liters
                                      gallons (7.57 liters) of Side-A   ASTM D2369-81
                                      and One 1 gallon (3.78 liters)
                                      can of Side-B

              15-Gallon Kit           Two 5 gallon (18.9 liters)   Carbon Steel: Use SSSP Guidelines for surface preparation.
                                      pails of Side-A and One 5   Acceptable systems include SP-6 (Commercial Blast), SP-3
                                      gallon (18.9 liters) pail of   (Power Tool/Hand Tool),  SSSP-SP-2, 3, 6 or SP-12 (WJ-3).
                                      Side-B
                                                                 Aluminum: Remove oil, grease, dirt and other contaminants
                                                                 with neutral detergent and treat with Alondine  1200 or equal.
                                                                                                       ®
                                                                 Light abrasive blasting is also acceptable.
            Color
            Side-A: Grey, Side-B: Clear                          Galvanized Steel: Remove all contaminants such as oil,
                                                                 grease, dirt or residues with a neutral detergent and treat
            Coverage                                             with Galvaprep .  Light abrasive blasting is also acceptable.
                                                                              ®
            The approximate coverage is 1 gallon/300 sqft (0.14  l/sqm)
            or 300 sqft/gallon. Coverage rate will depend on surface   Existing Coatings: Use SSSP guidelines for re-coating
            roughness and porosity.                              methods, recommended systems are SP-7 Abrasive blast or
                                                                 SP-3 Power Tool cleaning. Pressurized water at 2000 psi may
            Surface Preparation                                  also be used in conjunction with abrasive blasting or Power
            In general, coating performance is directly proportional to   tool cleaning. Apply a test patch to check adhesion before
            surface preparation. All surfaces must be free of oil, grease,   topcoating.
            dirt and other contaminants. Refer to General Guidelines for
            complete information.                                Concrete: Pressure wash (2000-3000 psi) with clean fresh
                                                                 water in conjunction with biodegradable cleanser if necessary



        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363                                        Section 2.5
        info@polycoatusa.com  |  www.polycoatusa.com