Page 14 - tmp
P. 14
TECHNICAL DATA SHEET I SECTION 2.1
METAL PRIMER 130
Two Component,
Polyurethane Metal Primer
Product Description
Metal Primer 130 is a two component, liquid applied, urea Technical Data (Based on Draw Down Film)
polyurethane primer. Polycoat Products manufactures
products in different VOCs ranging from 100 to 340 gms/liter Coverage Rate 1 gal/300 sqft
to comply with VOC requirement in various regions. Make 0.14 l/sqm
sure to use the correct grade of product which complies with
3 ± 1 mils
VOC regulations/requirements applicable as per federal, state, Dry Film Thickness per 76 ± 25 microns
statutory, counties, cities and local bodies at the place of Coat
installation. This product is NOT for sale in California or any
location where a VOC of 360 gms/liters is not acceptable. Mixing Ratio by Volume 1A : 3B
Features Pot Life at 75ºF (24ºC), 20-30 min
50% RH
• Low Odor
• Quick Drying Hardness, ASTM D2240 70 ± 5 Shore D
Typical Uses
Specific Gravity,
• Glass Reinforced Plastics Side-A 1.06 ± 0.1
• Metal Side-B 1.47 ± 0.1
• Polyurethane Elastomeric Surfaces
Total Solids by Weight, 75 ± 3%
ASTM D2369
Packaging
Total Solids by Volume, 62 ± 3%
1-Gallon Kit One - 1 quart can of Side-A
Clear Liquid, net 0.25 gallon ASTM D2697
(0.95 liters) and Three - 1
quart cans of Side-B Off Viscosity at 75°F (24°C) 500 ± 200 cps
White Liquid, net 0.25 gallon Side-A & Side B
(0.95 liters) each can Combined 2500 ± 500 cps
4-Gallon Kit One - 1 gallon can of Side-A Volatile Organic
Clear Liquid, net 1 gallon Compounds, 3 lb/gal
(3.78 liters) and One - 5 ASTM D2369-81 360 gm/liters
gallon pail of Side-B Off-
White Liquid, net 3 gallon
(11.34 liters)
Color combined components should be thoroughly mixed using a
Side-A: Clear, Side-B: Off-White mechanical mixer at slow speed or for at least 5 minutes if
mixed by hand. Do not mix in an up and down motion.
Coverage
The approximate coverage is 1 gallon/300 sqft (0.14 l/sqm). Application
Coverage rate will depend on surface roughness and porosity. Metal Primer 130 should be applied at the rate of 1 gallon/300
sqft (0.14 l/sqm) (mixture of Side-A & Side-B). It can be applied
Surface Preparation using an airless sprayer, brush, or phenolic resin core roller.
Remove all contaminant, oil and grease from substrate. Refer
to General Guidelines for complete information. Allow Metal Primer 130 to become nearly tack free before
applying the coating. Recommended surface temperature
Mixing should be greater than 50°F (10°C). If Metal Primer 130 is
Metal Primer 130 may not be diluted under any circumstance. allowed to dry completely, reprime the surface before
The volume mixing ratio: 1 part Side-A to 3 parts Side-B proceeding.
(1A:3B). Metal Primer 130 Side-B should be thoroughly mixed
prior to combining to ensure a homogeneous material. The Metal Primer 130 is very sensitive to heat and moisture. Higher
POLYCOAT PRODUCTS TEL 562.802.8834 | FAX 562.921.7363 Section 2.1
info@polycoatusa.com | www.polycoatusa.com