TECHNICAL DATA SHEET  I SECTION 8.3
                                                                                            POLYEURO  1050H
                                                                                                          ®
                                                                 Polyurea Polyurethane Copolymer Protective Coating





            Product Description
            Polyeuro  1050H has NSF-61 approval for direct contact with   Technical Data (Based on Draw Down Film)
                   ®
            potable water, and is recommended for use as a coating or   Mix Ratio by Volume                   1A : 2B
            lining on suitably primed carbon steel, non-ferrous metal and   Solids Content                     100%
            concrete. Polyeuro  1050H offers a tack-free time of less than
                            ®
            five minutes and exhibits 20-30% elongation upon curing with   Gel Time, 100 ± 10ºF (-12.2ºC)  40-80 seconds
            65 Shore D hardness.                                  Tack-Free Time @ 70ºF  (21ºC), 40mils  max 5 minutes
             Features                                             Service Time @ 70ºF (21ºC)               24-48 hours
              •  100% Solids                                      Viscosity at 100°F (32ºC), ASTM D445-79:  125 ± 50 cps
                                                                  Side-A
              •  Abrasion and Impact Resistant                    Side-B                                  500 ± 50 cps
              •  Chemical Resistant                               Spcific Gravity, ASTM D4659:
              •  High Build, Quick Dry                            Part-A                                     1.2 max
              •  Horizontal Surface Application                   Part-B                                     1.05 max
              •  Low Temperature Flexibility                      Flash Point                           > 200°F (93.3°C)
              •  Plural Component Spray Application               Hardness, ASTM D2240                   65 ± 5 Shore D

             Typical Uses                                         Dry Film Thickness per Coat              20-100 mils
                                                                  VOC Content, ASTM D412                      0 gm/l
               •  Canals, Dams & Basins
                                                                                                         2800 ± 200 psi
               •  Concrete/Steel                                  Tensile Strength, ASTM D412          19.042 ± 1.37 MPa
               •  Food Processing Facilities
               •  Lakes, Ponds and Water Containment              Elongation, ASTM D412                     25 ± 10%
                                                                                                           400 ± 50 pli
               •  Leach Tanks                                     Tear Strength, ASTM D624               69.9 ± 8.8 kNm
               •  Man Holes
               •  Mining                                          Sag Resistance                            Excellent
               •  Pen Stocks                                      Dry Time @ 70ºF (21ºC): to touch         20 minutes
               •  Petrochemical Plants                            Dry Time @ 70ºF (21ºC): for light foot traffic  1 hour
               •  Pipelines Coating (Internal)                    Dry Time @ 70ºF (21ºC): for heavy foot traffic  24 hours
               •  Power Plants                                    Cured to Service                           24 hours
               •  Pulp and Paper Plants
               •  Secondary Containment                           Maximum Recoat Period                      24 hours
               •  Water and Wastewater Treatment Plants           Full Cure                                 120 hours
               •  Water-Storage Tanks                             Surface Temperature Resistance
                                                                  Immersion                               120ºF  (49°C)
             Typical Systems                                      Dry                                     180ºF (82°C)
             CARBON STEEL                                         Humidity Tolerance on Application            <85%
             Primer: Polyprime 3042                               Material Temperature Required for Application:
                          ®
             Finish: Polyeuro  1050H                              Activator                                95 to 105ºF
             CONCRETE                                                                                      (35 to 40°C)
             Primer: Polyprime 3042                               Base                                     95 to 120ºF
             Finish: Polyeuro  1050H                                                                       (35 to 49°C)
                          ®
             Refer to Specification Guide for further detail.     Allowable Ambient Air Temp for Application
                                                                  Maximum                                 120ºF (49°C)
             Packaging                                            Minimum                                 25ºF (-3.9°C)
             160-gallon kit  One 55 Gallon Drum, containing 53.4
                             gallons (202.1 liters) of Side-A and.   Estimating Formula: (1600 sqft per gal /Dry Mil Thickness) x
                             two 55 Gallon Drums of Side-B, each   Solids Content = Application Rate per gallon.
                             containing 53.4 (202.1 liters) gallons
                                                                 Mixing
                                                                         ®
                                                                 Polyeuro  1050H may not be diluted under any circum-
            Colors                                               stances. Use appropriate cleaner for purge line and flushing
            Off-white with a medium sheen gloss.                 of equipment and if spraying stops for periods exceeding
                                                                                                              ®
                                                                 the pot life of the material. Thoroughly mix Polyeuro  1050H
            Coverage                                             Side-B material with air driven power equipment until a
            Polyeuro  8245 may be applied at any rate to achieve desired   homogeneous mixture and color is obtained. Opened material
                   ®
            thickness. Theoretical coverage for 1 mil (0.254 microns)   must be used within 1-2 days due to moisture sensitivity.
            thickness is one gallon per 1600 sqft (3.78 liters per 149 sqm).  Side-B must be thoroughly agitated for at least thirty (30)

        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363                                        Section 8.3
        info@polycoatusa.com  |  www.polycoatusa.com
   126   127   128   129   130   131   132   133   134   135   136