Page 9 - tmp
P. 9

TECHNICAL DATA SHEET
                                                                                        THEMECOAT  757-FR
                                                                                                         ®
                                                                            Fire Retardant Two Component Modified
                                                                                         Polyurea Protective Coating



            PRODUCT DESCRIPTION
            Themecoat  757-FR is a Class 1 fire-rated, two component,   TECHNICAL DATA (Based on Draw Down Films)
                     ®
            1:1, 100% solids, elastomeric, fast set, liquid applied, modified   Mix Ratio                    1A : 1B
            polyurea liner system for EPS, metal, concrete, fiberglass and
            wood surfaces.                                        Pot Life                               3-6 seconds
            FEATURES                                              Tack Free Time                       10-30 seconds
              •  Abrasion and Impact Resistant                    Recoat Time                             0-12 hours
              •  Chemical Resistant                               Viscosity at 150-160ºF
              •  High Build                                       (66.6-71ºC), Brookfield:
              •  Low Temperature Flexibility                      Side-A                                 150 ± 50 cps
                                                                  Side-B
                                                                                                         200 ± 20 cps
              •  Meets ASTM E-84 Class 1 Fire Test Criteria
              •  Quick Drying                                     Density (Side A & B                    13.03 lbs/gal
                                                                                                                  3
              •  Seamless                                         Combined)                            (1560  kgs/m )
              •  Tough and Elastomeric                            Flash Point                                 >200ºF
            TYPICAL USES                                                                                    (>93.3ºC)
              •  Cargo Holds                                      Hardness, ASTM D-2240*               50 ± 5 Shore D
              •  Cargo liners                                     Tensile, ASTM 412-C*                 1600 ± 200 psi
              •  EPS Architectural Shapes                                                               (11 ± 1.4 MPa)
              •  Industrial Floorings                             Elongation, ASTM 412-C*                 45% ± 20%
              •  Truck Bed Surfaces                               Tear, ASTM 624-C*                       350 ± 20 pli
              •  Utility Vehicles                                                                      (62 ± 3.5 kN/m)
              •  Walkways                                         Service Temperature - Dry              -20 to 250ºF
              •  Waterproof Decking                                                                   (-29ºC to 121ºC)
            PACKAGING
            10-gallon kit: 5 gallon (18.9 liters) pail of Side-A, 5 gallon pail   (*These physical properties from sample sprayed with Graco Foam   Cat
            (net fill 4.5 gal, 17 liters) of Side-B and 1 gallon can (net fil 0.5   200 @ 2000 psi (32 MPa) minimum, with Gusmer GX7-400 mechanical
                                                                   purge gun @ 150-160°F (66-72ºC).    Different machine and parameter will
            gal, 3.78 liters) of Side-C.                           change these properties.   User should perform their own  independent
                                                                   testing as properties are approximate.)
            100-gallon kit: One 50 gallon (189 liters) drum of Side-A), one
            50 gallon drum (net fil 45 gal, 170 liters) of Side-B and one 5
            gallon pail of Side-C (18.9 liters).
                                                                 surface preparation. Polyurea coatings rely on the structural
            COLOR                                                strength of the substrate to which they are applied. All sur-
            Dolphin Gray. Custom colors are available upon request.   faces must be free of dust, dirt, oil, grease, rust, corrosion
            Color Packs, when used, must be added to Side-B. Due to its     and other contaminants. When coating substrates previously
            aromatic composition, Themecoat  757-FR will tend to yel-   used, it is important to consider the possibility of substrate
                                         ®
            low or darken in color and will become flat after exposure to   absorption, which may affect the adhesion of the coating
            UV light. Themecoat  757-FR may be topcoated within twelve   system, regardless of the surface preparation. Polycoat
                             ®
            hours of application with an aliphatic polyurethane/polyurea   recognizes the potential for unique substrates from one project
            coating for a colorfast finish.                      to another. The following information is for general reference,
            MIXING                                               and for project-specific questions, contact Polycoat.
            Themecoat  757-FR may not be diluted under any circum-
                     ®
            stances. Thoroughly  mix   Themecoat  757-FR Side-A,   NEW AND OLD CONCRETE:
                                               ®
                                                                 Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5. New
            Side-B  and Side-C with air driven power equipment until a   concrete must be cured for 28 days prior to product applica-
            homogeneous mixture and color is obtained.           tion. Surface must be clean, dry, sound and offer sufficient
            For a 10 gallon kit (37.8 liters), mix for 5 minutes. For a 100   profile for product adhesion. Remove all dust, dirt, oil, form
            gallon (378 liters) kit, mix for 20 minutes.         release agents, curing compounds, salts, efflorescence,
                                                                 laitance and other foreign matter by shotblasting and/or
            COVERAGE                                             suitable chemical means, in accordance with local chemical
            Themecoat  757-FR may be applied at any rate to achieve   regulations. Rinse thoroughly, to achieve a pH between 8.0 and
                      ®
            desired thickness. Theoretical coverage for 1 mil thickness  is   11.0. Allow to dry completely. If old concrete has a surface that
            one gallon per 1600 sqft (3.78 liters per 149 sqm).  has deteriorated to an unacceptably rough surface, Polycoat
                                                                                                        ®
            SURFACE PREPARATION                                  Products PC-260 or a mixture of Polyprime  21 and sand
            In general, coating performance and adhesion are directly   should be used as a repair agent for cracks, spalls, bug holes
            proportional to surface preparation. Most failures in the   and voids. Upon full cure of the repair agent, prime the entire
            performance of surface coatings can be attributed to poor   surface intended for coating.


        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363
        info@polycoatusa.com  |  www.polycoatusa.com