Page 25 - Polycoat 10.2 Technical Data Sheet Polycaulk 82
P. 25

TECHNICAL DATA SHEET
                                                                                         POLYEURO  MPL 501
                                                                                                       ®
                                                               Two Component Modified Polyurea Protective Coating





            Product Description
            Polyeuro  MPL 501 is a two component, 1:1, 100% solids, fast   Technical Data (Based on Draw Down Film)
                   ®
            set, liquid applied, modified polyurea-liner system for metal,   Mix Ratio by Volume              1A : 1B
            concrete, fiberglass and wood surfaces.               Pot Life @ 150ºF (65.5ºC), 50% R.H.     2-4-Seconds
             Features                                             Tack-Free Time (150 mils thickness)    10-30 Seconds
              •  Abrasion and Impact Resistant                    Recoat Time                              0 - 12 hours
              •  Chemical Resistance                              Viscosity at 150-160°F (66.5-71°C)
              •  High Build                                       Side-A                                  120 ± 20 cps
                                                                  Side-B
                                                                                                          200 ± 20 cps
              •  Low-Temperature Flexibility
              •  Quick Drying                                     Density  (Side-A & Side-B Combined)      9.12 lbs/gal
              •  Seamless                                         Specific Gravity (Side-A & Side-B Combined)   1.10
              •  Tough and Elastomeric                            Flash Point                           > 200°F (93.3°C)
                                                                  Hardness, ASTM D2240                   55 ± 5 Shore D
             Typical Uses
                                                                  Tensile Strength, ASTM D412*           2800 ± 200 psi
               •  Boat Linings                                                                         19.31 ± 1.37 MPa
               •  Cargo Holds                                     Elongation, ASTM D412*                  200% ± 20%
               •  Cargo Liners                                    Tear Resistance, ASTM D412*              400 ± 50 pli
               •  Containment Areas                                                                     69.93 ± 8.8 kNm
               •  Encapsulation of Fiberglass Bodies and Polystyrene   Service Temperature Dry           -20ºF to 250ºF
                Foams                                                                                    - 4.0°C to 93°C
               •  Horse Trailers                                  Water Vapor Permeability ASTM E96        0.69 Perms
               •  Industrial Floorings                            *These physical properties from sample sprayed with Graco Foam Cat 200 @ 2000 psi minimum,
               •  Truck-Bed Liner                                 with Gusmer GX7-400 mechanical purge gun @ 150-160°F (65°C to 71°C). Different machine and
               •  Utility Vehicles                                parameter will change these properties.  User should perform their own independent testing as
                                                                  properties are approximate.
               •  Walkways
               •  Waterproof Decking
                                                                 proportional to surface preparation. Most failures in the
             Packaging                                           performance of surface coatings can be attributed to poor
                                                                 surface preparation. Polyurea coatings rely on the structural
                                                                 strength of the substrate to which they are applied. All sur-
              10-gallon kit   5 gallons (18.9 liters) Side-A and 5   faces must be free of dust, dirt, oil, grease, rust, corrosion
                              gallons (18.9 liters) Side-B
                                                                 and other contaminants. When coating substrates previously
                                                                 used, it is important to consider the possibility of substrate
              100-gallon kit  50 gallons (189 liters) Side-A and 50   absorption, which may affect the adhesion of the coating
                              gallons (189 liters) Side-B        system, regardless of the surface preparation. Polycoat
                                                                 recognizes the potential for unique substrates from one project
                                                                 to another. The following information is for general reference,
                                                                 and for project-specific questions, contact Polycoat.
            Colors
            Clear/Neutral/Tan/Grey/Black. Custom colors are available   NEW AND OLD CONCRETE
            upon request.  Color Packs, when used, must be added to   Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5.  New
            Side-B.                                              concrete must be cured for 28 days prior to product applica-
            Due to its aromatic composition, Polyeuro MPL 501 will tend to   tion. Surface must be clean, dry, sound and offer sufficient
            yellow or darken in color and will become flat after exposure to   profile for product adhesion. Remove all dust, dirt, oil, form
            UV light. Polyeuro MPL 501 may be top-coated within twelve   release agents, curing compounds, salts, efflorescence,
            hours of application with an aliphatic polyurethane/polyurea/  laitance and other foreign matter by shotblasting and/or
            polyaspartic coating for a colorfast finish.         suitable chemical means, in accordance with local chemical
                                                                 regulations. Rinse thoroughly, to achieve a pH between 8.0 and
            Coverage                                             11.0. Allow to dry completely. If old concrete has a surface that
            Polyeuro MPL 501 may be applied at any rate to achieve desired   has deteriorated to an unacceptably rough surface, Polycoat
            thickness.  Theoretical coverage for 1 mil (0.254 microns)   Products PC-260 or a mixture of Polyprime 21 and sand should
            thickness is one gallon per 1600 sqft (3.78 liters per 149 sqm).  be used as a repair agent for cracks, spalls, bug holes and
                                                                 voids.
            Estimating Formula: (1600 sqft per gal /Dry Mil Thickness) x
            Solids Content = Application Rate per gallon.        CONCRETE SURFACE PREPARATION REFERENCE:
            Surface Preparation                                  ASTM D4258 - Standard practice for cleaning concrete
            In general, coating performance and adhesion are directly   ASTM D4259 - Standard practice for abrading concrete


        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363