Page 128 - Polycoat 1.1 Table of Contents
P. 128

TECHNICAL DATA SHEET  |  Section 6.8
                                                                                                PC-440 / 440SC
                                                                                  ICC-ES Evaluated Base Membrane
                                                                                    For Class A/B Fire Rated System



            Product Description
            PC-440/440SC is a single component, liquid applied, moisture-  Technical Data (Based on Draw Down Film)
            cured, aromatic polyurethane elastomeric waterproofing base
            membrane, designed for use in most areas of California to                       PC-440        PC-440SC
            be in compliance with air quality standards. Make sure to
            use the correct grade of product which complies with VOC
            regulations/requirements applicable as per federal, state,   Coverage Rate  1 gal/100 sqft  1 gal/100 sqft
            statutory, counties, cities and local bodies at the place of                 0.41 l/sqm       0.14 l/sqm
            installation.
                                                                   Dry Film Thickness    11 ± 2 mils     14 ± 1 mils
             Features                                              per Coat               279 ± 50         355 ± 50
                                                                                                           microns
                                                                                           microns
              •  Economical
              •  Moisture Cured                                    Hardness,         55 ± 5  Shore A  55 ± 5  Shore A
              •  Seamless Waterproofing Membrane                   ASTM D2240

                                                                   Tear Resistance,     170 ± 25 pli     120 ± 25 pli
             Typical Uses                                          Die C, ASTM D624  28.9 ± 4.4 kN/m  21.0 ± 4.4 kN/m
               •  Concrete
               •  Masonry Surfaces                                 Tensile Strength,   800 ± 100 psi    500 ± 100psi
               •  Metal                                            ASTM D412          5.5 ± 0.7 MPa    3.4 ± 0.7 MPa
               •  Plywood
               •  Wood                                             Ultimate Elongation,   500 ± 50%       400 ± 50%
                                                                   ASTM D412
            Packaging                                              Specific Gravity       1.26 ± 0.1      1.30 ± 0.1

             5-Gallon                5 gallon (18.9 liters) pail   Total Solids by         81 ± 2%        92.7 ± 2%
                                                                   Weight,
             55-Gallon               55 gallon drum, net fill 50   ASTM D2369
                                     gallons (189 liters)
                                                                   Total Solids by         71 ± 2%         87.7 ± 2%
                                                                   Volume,
            Color                                                  ASTM D2697
            Grey or Tan
            Surface Preparation                                    Viscosity at 75°F   6500 ± 2000 cps  6500 ± 2000 cps
            Refer to General Guidelines for complete information.  (24°C)
            Mixing
            Before application, mix PC-440/440SC using a mechanical   Volatile Organic   2.01 lb/gal      0.78 lb/gal
            mixer at slow speed. Mix PC-440/440SC thoroughly until a   Compounds,     240 gm/liters     94 gm/liters
            homogeneous mixture and color is attained. Use care not to   ASTM D2369-81
            allow the entrapment of air into the mixture. Do not mix in
            an up and down motion.
            Application
            For best results, use a squeegee or notched trowel. A phenolic   between coats, it is imperative that recoating be done within
            resin core roller may be used but extra care should be taken not   48 hours. If re-coat window has passed, then solvent wipe
            to trap air which may result in bubbles. Requires a continuous   the surface with VOC-compliant solvent and re-prime with
            coating application to minimize lines and/or streaking.  Polyprime  U.
                                                                          ®
            It is recommended to apply an aggregate of washed, dry,
            rounded sand, approximately 16 or 20 mesh (0.84-1.19 mm),   Curing
            6.5+ Mohs minimum hardness at a rate of 20 lbs/100 sqft  (1   At 75°F (24°C) and 50% relative humidity, allow coating to cure
            kg/sqm) or as required to achieve a slip-resistant finish, into   16 hours before proceeding to subsequent coats. Cure time
            the wet second coat, covering it completely. Broadcast sand   will vary depending on temperature and humidity. If more
            until refusal and when the coating is dry, remove extra loose   than 48 hours passes between coats, reprime the surface with
                                                                          ®
            sand, preferably by vacuum.                          Polyprime  U before proceeding.
            Most applications require two coats. To obtain proper adhesion   If accelerated curing is required, add one quart of PC-50 in


        POLYCOAT PRODUCTS TEL 562.802.8834  |  FAX 562.921.7363                                           Section 6.8
        wpsales@polycoatusa.com  |  www.polycoatusa.com
   123   124   125   126   127   128   129   130   131   132   133