Page 44 - tmp
P. 44

GUIDE SPECIFICATIONS  |  Section 2.8
                                                                                               POLYDECK  355
                                                                                                              ®





                                                                 a urethane grade environmentally safe solvent, as permitted
            FINISHED SYSTEM                                      under local regulations, immediately after use. Uncured
            When applied as directed above, the Polydeck  355 Pedestrian   materials are sensitive to heat and moisture. The substrate
                                                 ®
            Traffic Deck System will provide minimum 50 to 65 ± 5 dry   must be structurally sound and sloped for proper drainage.
            mils (1270 to 1651 ± 125 dry microns), exclusive of aggregate,   Polycoat Products assumes no liability for substrate defects.
            of superior waterproofing protection, and the assurance of   Field visits by Polycoat Products personnel are for the purpose
            a Class B Fire Rating over 5/8” (1.59 cm) or 19/32” (1.51 cm)   of making technical recommendations only and are not to
            plywood or a Class A Fire Rating on concrete. Requires a   supervise or provide quality control on the job site.
            continuous coating application to minimize lines and/or
            streaking. Any optional adhesion test is to be performed seven   Warning
            days after product application.                      The products in this system contain Isocyanates, Solvents, Epoxy Resin,
                                                                 and Curatives.
            Limitations
            The following conditions must not be coated with Polycoat
            Products deck coating systems or products: on grade slabs,
            split slabs with buried membrane, sandwich slabs with
            insulation, slabs over unvented metal pan, magnesite, or
            concrete with a structural integrity less than 3000 psi. Asphalt
            surfaces and asphalt overlays may be coated with Polycoat
            decking systems if first coated with the Polycoat™ PC-IM 129.

            Concrete must exhibit 3000 psi minimum strength. Concrete
            surfaces to be coated must be trowel finished in compliance with
            the American Concrete Institute (except that hand troweling
            is not required), followed by a fine-haired brooming, left free
            of loose particles, and shall be without ridges, projections,
            voids and concrete droppings that would be mechanically
            detrimental to coating application or function. New concrete
            must be cured for 28 days.
            Polycoat Products coating systems should not be subjected
            to rising water tables or hydrostatic pressure on slab-on-
            grade decks. The only acceptable grade of plywood is APA
            rated exterior grade or better. The appearance and physical
            characteristics of the plywood and grade should be considered.
            Plywood should be new or cleaned and sanded (see General
            Guidelines). The coating should be applied at least 5°F (3°C)
            above the dew point.
            Coverage rates recommended are based on lab conditions,
            applied at 75°F (24°C) ambient temperature and are intended
            to be minimum coverage rates on clean, smooth plywood, and
            are exclusive of additional amounts needed to fill potholes,
            spalling, scaling, rough and irregular surfaces.  Porosity and
            roughness of the substrate, aggregate size, and product
            temperature will affect coverage rates. Material mil thickness
            rates are calculated on theoretical coverage for a smooth
            substrate and do not account for the actual texture or substrate
            conditions in the field or at the time of application.  Sample
            mockups on the projects are recommended to determine
            the exact coverage rates necessary to waterproof the deck
            to acceptable standards. Equipment should be cleaned with