ESR-2785                                                                               Page 5 of 11

                4.2.3  Application of Systems:  Application  of systems described in this report must comply  with the
                manufacturer’s published installation instructions, this report and the applicable code.
                4.2.3.1  Polycoat System: System details and application rates of products must be as specified in Table 1.
                For additional details on system installation, refer to Polycoat’s Technical Data Sheets and System Details.
                4.2.3.2  Polytuff System: System details and application rates of products must be as specified in Table 2.
                For additional details on system installation, refer to Polytuff’s Technical Data Sheets and System Details.
                4.2.3.3  ENDURIT DECK Pro Walking Deck System: System details and application rates of products must
                be as specified in Table 3. For additional details on system installation, refer to BESSERN Building Products’
                Technical Data Sheets and System Details.
                4.2.4  Method of Repair: Damaged areas are permitted to be repaired by cutting or grinding out an area
                extending 6 inches (152 mm) beyond the damage; cleaning with a urethane-active solvent; and applying the
                primer, base membrane, and topcoats in the same manner  as described in the published installation
                instructions and this report.
                4.2.5  One-hour Fire-resistance-rated Construction: The Polydeck  355, Polydeck  400, Polydeck  600,
                                                                                                           ®
                                                                               ®
                                                                                             ®
                                       ®
                Polydeck  610, Flexideck  P-A, Flexideck  P-B, ENDURIT DECK Pro-WM 70 S and ENDURIT DECK Pro-
                        ®
                                                      ®
                WM 70 R walking deck systems, as described in Tables 1,  2 and 3, are permitted to be substituted for the
                double wood floor described in Item 13 of Table 721.1(3) of the IBC [Table 720.1(3) of the 2009 IBC], when
                installed in accordance with this report over  /4-inch-thick (19 mm), Exterior 1 plywood supported by minimum
                                                       3
                2-by-10 joists spaced a maximum of 16 inches (406 mm) on center.
                4.2.6  Roof Covering Fire Classification: When installed in accordance with this report, the assemblies
                have the fire classifications noted in Tables 1, 2 and 3.
                4.2.7  Wind Resistance: The maximum allowable wind resistance pressure is limited by the capacity of the
                roof deck construction. The roof deck must be designed to withstand wind pressures in accordance with IBC
                Section 1609.5.1.
                                                                                                          ®
                                                                                              ®
                4.3  Ceramic Tile Underlayment and Shower Sub-pan Lining Polycoat-Aquatight , Flexideck  P-TW
                and ENDURIT DECK Pro-UTM Underlayment Systems:
                4.3.1  Preparation of Substrates: See Section 4.2.1.
                4.3.2  Application of Systems: See Section 4.2.3 and Tables 1 through 3.
                4.3.3  Method of Repair: See Section 4.2.4.
            5.0 CONDITIONS OF USE:

             The products described in this report comply with, or are suitable alternatives to what is specified in, those codes
             listed in Section 1.0 of this report, subject to the following conditions:
               5.1  Installation must comply  with this  report, the manufacturer’s published installation instructions and the
                   applicable code. If there is a conflict between the manufacturer’s published installation instructions and this
                   report, this report governs.
               5.2  The products are manufactured in Santa Fe Springs, California and Bedford, Texas under a quality control
                   program with inspections by ICC Evaluation Service, LLC.
            6.0 EVIDENCE SUBMITTED

               6.1  Polycoat, Polytuff and ENDURIT DECK Pro Walking Deck Systems: Data in accordance with the ICC-
                   ES Acceptance Criteria for Walking Decks (AC39), dated October 2013 (editorially revised November 2020).
               6.2  Polycoat-Aquatight , Flexideck  P-TW and ENDURIT DECK Pro-UTM Underlayment Waterproofing
                                                ®
                                     ®
                   Systems: Data in accordance with the ICC-ES Acceptance Criteria for Waterproof Membranes for Flooring
                   and Shower Lining (AC115), dated June 2003 (editorially revised February 2021).
            7.0 IDENTIFICATION

               7.1  The ICC-ES mark of conformity, electronic labeling, or the evaluation report number (ICC-ES ESR-2785)
                   along with the name, registered trademark, or registered logo of the report holder (Polycoat Products) or
                   listee (Poly-Tuff International or BESSERN Building Products) must be included in the product label.

               7.2  In addition, individual containers of each component bear a label indicating the product designation, the
                   batch number, and shelf life information in the form of an expiration date.