NEW AND OLD CONCRETE                                  Application
        Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5.  New   Both Side-A and Side-B materials should be preconditioned
        concrete must be cured for 28 days prior to product applica-  to 90-100°F (32-42°F) before application.
        tion. Surface must be clean, dry, sound and offer sufficient
        profile for product adhesion. Remove all dust, dirt, oil, form   Both Side-A and Side-B materials should be continuously
        release agents, curing compounds, salts, efflorescence,   agitated before and during application. Agitate at least one
        laitance and other foreign matter by shotblasting and/or   hour prior to application using heavy duty drum agitator.
        suitable chemical means, in accordance with local chemical   Both Side-A and Side-B lines must have filters removed. Use
        regulations. Rinse thoroughly, to achieve a pH between 8.0 and   a round pattern disc for spraying. Orifice diameter must be
        11.0. Allow to dry completely. If old concrete has a surface that   0.042” or greater.
        has deteriorated to an unacceptably rough surface, Polycoat
        Products PC-260 or a mixture of Polyprime 21 and sand should   Recommended surface temperature must be at least 5°F (3°F)
        be used as a repair agent for cracks, spalls, bug holes and   above the dew point.
        voids.  Upon full cure of the repair agent, prime the entire   Polyeuro  MPL-11 FR should be applied using a plural
                                                                      ®
        surface intended for coating.                         component, heated, high pressure 1:1 spray mixing equip-
                                                              ment like Graco’s Reactor, Glass Craft or other equivalent
        CONCRETE SURFACE PREPARATION REFERENCE                machine may be used.
        ASTM D4258 - Standard practice for cleaning concrete ASTM
        D4259 - Standard practice for abrading concrete ASTM D4260 -   Both Side-A and Side-B materials should be sprayed at a
        Standard practice for etching concrete ASTM F1869 - Standard   minimum of 2000 psi and at temperatures above 150°F (66°C).
        test method for measuring moisture vapor emission rate of   Adequate pressure and temperature should be maintained
        concrete                                              at all times.
                                                                     ®
        ICRI 03732 - Concrete surface preparation             Polyeuro  MPL-11 FR should be sprayed in smooth, multi-
                                                              directional passes to improve uniform thickness and ap-
        WOOD                                                  pearance.
        All wood should be clean, dry and free of any knots, splinters,
        oil, grease or other contaminants.  Splintered or rough areas  Storage
                                                                     ®
        should be sanded.  Knots should be repaired using Polycoat   Polyeuro  MPL-11 FR has a shelf life of twelve (12) months
        Products PC-260 with sand.  Upon full cure of the repair agent,   from date of manufacture, in factory-sealed containers.  at a
        prime the entire surface intended for coating.        temperature between 60-95°F (15-35°C).
                                                              Side-A and Side-B drums are recommended to be stored
        STEEL (ATMOSPHERIC AND IMMERSION EXPOSURE)
        Remove all oil, grease, weld spatters and round off any sharp   above 60°F (15°C). Avoid freezing temperatures.
        edges from surface. Minimum surface preparation is Near   Store drums on wooden pallets to avoid direct contact with
        White Metal Blast Cleaning per SSPC-SP10/NACE 2. Opti-mum   the ground. If stored for a long period of time, rotate Side-A
        surface profile is 2-3 mils. Prime with recommended primer   and Side-B drums regularly.
        and spray Polyeuro  MPL-11FR on to any bare metal the same
                        ®
        day as it is cleaned to minimize any potential flash rusting.  Limitations
                                                              Do not open until ready to use.
        GALVANIZED SURFACES                                   Both Side-A and Side-B containers must be fitted with a
        Clean and degrease any contaminated surfaces before   desiccant device during use.
        priming.  Do not blast galvanized surfaces with an abrasive
        grit. An adhesion test is recommended prior to starting the   Warning
        project. Primer may be needed, consult Polycoat.
                                                              This product contains Isocyanates and Curative Material.
        FIBERGLASS REINFORCED PLASTIC
        The gel coat should be lightly blasted or sanded with 80 grit
        sandpaper and cleaned.
        TEXTILES, CANVAS, FABRICS
        Adhesion to most fabrics, geothermal membranes and tex-
        tiles does not require a primer.
        NEW AND OLD CAST IRON:
        Blast with a steel grit and degrease before priming. Old cast
        iron is difficult to prepare for a satisfactory bond.  It can
        absorb oil and water soluble contaminants that will keep
        returning to the surface after the coating system has been
        applied and affect the coating system adhesion. An adhesion
        test is recommended prior to starting the project.
        MIXING
        Polyeuro  MPL-11 FR may not be diluted under any circum-
                ®
        stances. Thoroughly mix Polyeuro  MPL-11 Side-A and Side-B
                                     ®
        with air driven power equipment until a homogeneous mix-