NEW AND OLD CONCRETE Application
Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5. New Both Side-A and Side-B materials should be preconditioned
concrete must be cured for 28 days prior to product applica- to 90-100°F (32-42°F) before application.
tion. Surface must be clean, dry, sound and offer sufficient
profile for product adhesion. Remove all dust, dirt, oil, form Both Side-A and Side-B materials should be continuously
release agents, curing compounds, salts, efflorescence, agitated before and during application. Agitate at least one
laitance and other foreign matter by shotblasting and/or hour prior to application using heavy duty drum agitator.
suitable chemical means, in accordance with local chemical Both Side-A and Side-B lines must have filters removed. Use
regulations. Rinse thoroughly, to achieve a pH between 8.0 and a round pattern disc for spraying. Orifice diameter must be
11.0. Allow to dry completely. If old concrete has a surface that 0.042” or greater.
has deteriorated to an unacceptably rough surface, Polycoat
Products PC-260 or a mixture of Polyprime 21 and sand should Recommended surface temperature must be at least 5°F (3°F)
be used as a repair agent for cracks, spalls, bug holes and above the dew point.
voids. Upon full cure of the repair agent, prime the entire Polyeuro MPL-11 FR should be applied using a plural
®
surface intended for coating. component, heated, high pressure 1:1 spray mixing equip-
ment like Graco’s Reactor, Glass Craft or other equivalent
CONCRETE SURFACE PREPARATION REFERENCE machine may be used.
ASTM D4258 - Standard practice for cleaning concrete ASTM
D4259 - Standard practice for abrading concrete ASTM D4260 - Both Side-A and Side-B materials should be sprayed at a
Standard practice for etching concrete ASTM F1869 - Standard minimum of 2000 psi and at temperatures above 150°F (66°C).
test method for measuring moisture vapor emission rate of Adequate pressure and temperature should be maintained
concrete at all times.
®
ICRI 03732 - Concrete surface preparation Polyeuro MPL-11 FR should be sprayed in smooth, multi-
directional passes to improve uniform thickness and ap-
WOOD pearance.
All wood should be clean, dry and free of any knots, splinters,
oil, grease or other contaminants. Splintered or rough areas Storage
®
should be sanded. Knots should be repaired using Polycoat Polyeuro MPL-11 FR has a shelf life of twelve (12) months
Products PC-260 with sand. Upon full cure of the repair agent, from date of manufacture, in factory-sealed containers. at a
prime the entire surface intended for coating. temperature between 60-95°F (15-35°C).
Side-A and Side-B drums are recommended to be stored
STEEL (ATMOSPHERIC AND IMMERSION EXPOSURE)
Remove all oil, grease, weld spatters and round off any sharp above 60°F (15°C). Avoid freezing temperatures.
edges from surface. Minimum surface preparation is Near Store drums on wooden pallets to avoid direct contact with
White Metal Blast Cleaning per SSPC-SP10/NACE 2. Opti-mum the ground. If stored for a long period of time, rotate Side-A
surface profile is 2-3 mils. Prime with recommended primer and Side-B drums regularly.
and spray Polyeuro MPL-11FR on to any bare metal the same
®
day as it is cleaned to minimize any potential flash rusting. Limitations
Do not open until ready to use.
GALVANIZED SURFACES Both Side-A and Side-B containers must be fitted with a
Clean and degrease any contaminated surfaces before desiccant device during use.
priming. Do not blast galvanized surfaces with an abrasive
grit. An adhesion test is recommended prior to starting the Warning
project. Primer may be needed, consult Polycoat.
This product contains Isocyanates and Curative Material.
FIBERGLASS REINFORCED PLASTIC
The gel coat should be lightly blasted or sanded with 80 grit
sandpaper and cleaned.
TEXTILES, CANVAS, FABRICS
Adhesion to most fabrics, geothermal membranes and tex-
tiles does not require a primer.
NEW AND OLD CAST IRON:
Blast with a steel grit and degrease before priming. Old cast
iron is difficult to prepare for a satisfactory bond. It can
absorb oil and water soluble contaminants that will keep
returning to the surface after the coating system has been
applied and affect the coating system adhesion. An adhesion
test is recommended prior to starting the project.
MIXING
Polyeuro MPL-11 FR may not be diluted under any circum-
®
stances. Thoroughly mix Polyeuro MPL-11 Side-A and Side-B
®
with air driven power equipment until a homogeneous mix-
ture and color is obtained.
POLYCOAT PRODUCTS TEL 562.802.8834 | FAX 562.921.7363 Section 6.2
info@polycoatusa.com | www.polycoatusa.com