Page 41 - Polycoat 10.2 Technical Data Sheet Polycaulk 82
P. 41
TECHNICAL DATA SHEET
POLYEURO 1050H
®
Polyurea Polyurethane Copolymer Protective Coating
Product Description
Polyeuro 1050H has NSF-61 approval for direct contact with Technical Data (Based on Draw Down Film)
®
potable water, and is recommended for use as a coating or Mix Ratio by Volume 1A : 2B
lining on suitably primed carbon steel, non-ferrous metal and Solids Content 100%
concrete. Polyeuro 1050H offers a tack-free time of less than
®
five minutes and exhibits 20-30% elongation upon curing with Gel Time, 100 ± 10ºF (-12.2ºC) 40-80 seconds
65 Shore D hardness. Tack-Free Time @ 70ºF (21ºC), 40mils max 5 minutes
Features Service Time @ 70ºF (21ºC) 24-48 hours
• 100% Solids Viscosity at 100°F (32ºC), ASTM D445-79: 125 ± 50 cps
Side-A
• Abrasion and Impact Resistant Side-B 500 ± 50 cps
• Chemical Resistant Spcific Gravity, ASTM D4659:
• High Build, Quick Dry Part-A 1.2 max
• Horizontal Surface Application Part-B 1.05 max
• Low Temperature Flexibility Flash Point > 200°F (93.3°C)
• Plural Component Spray Application Hardness, ASTM D2240 65 ± 5 Shore D
Typical Uses Dry Film Thickness per Coat 20-100 mils
VOC Content, ASTM D412 0 gm/l
• Canals, Dams & Basins
2800 ± 200 psi
• Concrete/Steel Tensile Strength, ASTM D412 19.042 ± 1.37 MPa
• Food Processing Facilities
• Lakes, Ponds and Water Containment Elongation, ASTM D412 25 ± 10%
400 ± 50 pli
• Leach Tanks Tear, Die C, ASTM D624 69.9 ± 8.8 kNm
• Man Holes
• Mining Sag Resistance Excellent
• Pen Stocks Dry Time @ 70ºF (21ºC): to touch 20 minutes
• Petrochemical Plants Dry Time @ 70ºF (21ºC): for light foot traffic 1 hour
• Pipelines Coating (Internal) Dry Time @ 70ºF (21ºC): for heavy foot traffic 24 hours
• Power Plants Cured to Service 24 hours
• Pulp and Paper Plants
• Secondary Containment Maximum Recoat Period 24 hours
• Water and Wastewater Treatment Plants Full Cure 120 hours
• Water-Storage Tanks Surface Temperature Resistance
Immersion 120ºF (49°C)
Typical Systems Dry 180ºF (82°C)
CARBON STEEL Humidity Tolerance on Application <85%
Primer: Polyprime 3042 Material Temperature Required for Application:
®
Finish: Polyeuro 1050H Activator 95 to 105ºF
CONCRETE Base (35 to 40°C)
Primer: Polyprime 3042 95 to 120ºF
®
Finish: Polyeuro 1050H (35 to 49°C)
Refer to Specification Guide for further detail. Allowable Ambient Air Temp for Application
Maximum 120ºF (49°C)
Packaging Minimum 25ºF (-3.9°C)
160-gallon kit One 55 Gallon Drum, containing 53.4
gallons (202.1 liters) of Side-A and. Estimating Formula: (1600 sqft per gal /Dry Mil Thickness) x
two 55 Gallon Drums of Side-B, each Solids Content = Application Rate per gallon.
containing 53.4 (202.1 liters) gallons
Mixing
®
Polyeuro 1050H may not be diluted under any circum-
Colors stances. Use appropriate cleaner for purge line and flushing
Off-white with a medium sheen gloss. of equipment and if spraying stops for periods exceeding
®
the pot life of the material. Thoroughly mix Polyeuro 1050H
Coverage Side-B material with air driven power equipment until a
Polyeuro 8245 may be applied at any rate to achieve desired homogeneous mixture and color is obtained. Opened material
®
thickness. Theoretical coverage for 1 mil (0.254 microns) must be used within 1-2 days due to moisture sensitivity.
thickness is one gallon per 1600 sqft (3.78 liters per 149 sqm). Side-B must be thoroughly agitated for at least thirty (30)
POLYCOAT PRODUCTS TEL 562.802.8834 | FAX 562.921.7363